InoPurauto-16R uses the same extraction block as InoPurauto-24S with a sample yield of 1-16 and supports extraction of common samples, FFPE block and cfDNA.
It is also available for qPCR, digital PCR and general 96-Well PCR plate, and a set of pipetting parts suitable for the installation of various digital PCR chips, which can be freely selected according to the actual situation.
Wide Application Range
> Provides nucleic acid extraction of FFPE block, whole blood, plasma, feces, sputum, etc.
High Security
> The UV lamp contains sterilization components and the HEPA system provides effective filtration to prevent aerosol contamination during the experiment.
Prepackaged Reagent
> Supports the use of pre-packaged reagent directly on the machine. It automatically pierces the film and only needs to add sample and magnetic beads to complete the nucleic acid extraction.
Open Software Design
> It has a user authority management function that provides full control of the administrator and a visual interface design that offers comfortable use.
> It has an open software design suitable for most of the magnetic bead method nucleic acid extraction reagents on the market.
Supports PCR Setup
> Supports PCR, QPCR and ddPCR setups.
Technical Specifications
|
Model |
InoPurauto-16R |
|
Function |
Automatic pipetting and Nucleic acid extraction |
|
Extraction Principle |
Extraction method combined with magnetic rods and magnetic combs based on magnetic bead method and pipetting type |
|
Throughput |
1-16 |
|
Sample |
FFPE, whole blood, plasma, stool, sputum, etc |
|
Pre-Packaged Reagent |
Support the pre-packaged reagent to be directly on the machine and automatically prick the film |
|
Information Management |
Support external code scanner |
|
Visual Recognition |
Optional visual block can automatically identify the quantity and specification of consumables |
|
Sample Processing System |
1-15mL |
|
Minimum Elution Volume |
20μL |
|
Stability |
CV ≤5% |
|
Software Operation |
10-inch color touch screen, windows system software |
|
Account Management |
User authorization management, programs and instruments can be customized |
|
Instrument Port |
USB Port, LAN Port |
|
Pollution Control |
Built-in HPEA, UV Sterilization |
|
Power Supply |
AC 220V, 50Hz, Rated power 450W |
|
Extraction Temperature Control Purpose |
Used for incubation in the extraction process, such as lysis, elution, etc |
|
Extraction Temperature Control Temperature Control Range |
RT - 120°C |
|
Extraction Temperature Control Temperature Accuracy |
≤±1°C at 100°C |
|
Extraction Temperature Control Temperature Uniformity |
≤3°C at 100°C |
|
Extraction Temperature Control Temperature Stability |
≤±0.5°C at 100°C |
|
Reagent Refrigeration Purpose |
Used for reagent refrigeration and supports automatic refrigeration at startup |
|
Reagent Refrigeration Temperature Control Range |
4°C - 95°C |
|
Reagent Refrigeration Temperature Accuracy |
≤1°C at 4°C |
|
Reagent Refrigeration Temperature Uniformity |
≤1°C at 4°C |
|
Pipetting Block 1 Purpose |
Nucleic Acid Extraction |
|
Pipetting Block 1 Pipetting Range |
20 - 1000μL |
|
Pipetting Block 1 Precision |
20 μL≤2.5 % 100 μL≤1.25 % 500 μL≤0.4 % 1000 μL≤0.4 % |
|
Pipetting Block 1 Accuracy |
20 μL≤±5 % 100 μL≤±2 % 500 μL≤±1 % 1000 μL≤±1 % |
|
Pipetting Block 2 Purpose |
Automatic Pipetting |
|
Pipetting Block 2 Pipetting Range |
1 - 200μL |
|
Pipetting Block 2 Precision |
1 μL≤5 % 20 μL≤2 % 100 μL≤1 % 200 μL≤1 % |
|
Pipetting Block 2 Accuracy |
1 μL≤±12 % 20 μL≤±2 % 100 μL≤±1 % 200 μL≤±1 % |